Hydraulic Modeling and DMA

Isolated Zone Strategy

What is DMA and
Why Do We Isolate the Network?

DMA Segmentation

100%

Controllable Network

The DMA strategy digitalizes leak detection and pressure optimization processes by transforming your network into manageable cells; thus, by feeding the digital twin of the network with data from each region, it minimizes operational losses while maximizing infrastructure security.

Full Traceability

We precisely track minimum night flow values by measuring inlet-outlet flow differences in real-time.

Local Pressure Balance

We extend pipe life and minimize the number of failures with regional pressure modulation.

Rapid Leak Diagnosis

When an anomaly is detected, we shorten intervention time by directing teams directly to the leak zone.

GIS-Based Modeling

Digital DNA of the Network:
GIS Model Optimization

1
Topological Data Cleaning

We prepare data for analysis by extracting node errors and unoriented lines in GIS data using advanced algorithms.

2
Hydraulic Attribute Assignment

We create the physical skeleton of the model by pulling pipe diameter, material roughness, and elevation data from GIS layers.

3
Static Model Validation

We confirm the digital equivalent of the existing field situation by testing the prepared data in hydraulic solvers.

GIS Analysis
Data Accuracy 99.8%
Advanced Simulations

Critical State
Scenario and Impact Analysis

Fire Flow Testing

We simulate the capacity to maintain necessary flow and minimum service pressure when a fire occurs at any point in the network.

Critical Analysis
Pipe Burst Analysis

We pre-measure valve closure scenarios and the population affected by outages in the event of bursts in main transmission lines.

Risk Management
Connectivity Impact Measurement

We report the impact of connecting new residential areas to the existing network on pressure balance and water age digitally.

Investment Planning
DMA Management & Monitoring

24/7 Active
Automated Leakage Analysis

Real-time Leakage Calculation

We automatically calculate the difference between all inlet and outlet flow data of the isolated zone. This mathematical difference is the clearest indicator of physical losses in the network.

Night Flow (MNF) Analysis

By measuring base flow during night hours when consumption is lowest, we detect background leaks in the system and create alarms for threshold violations.

DMA Live Data Stream

Live MNF and Flow Analysis Chart

Leakage Sensitivity 0.1 l/s

For Solution

Call: +90 264 777 1 301

Working Hours

Mon - Fri 08:30 - 18:00

Our Email Address

info@scadasu.com

SCADASU logo
Solutions
Contact
Weekdays 08.30 - 18.00
Erenler Mh. 1173 Sk. No: 11 Erenler, TR
info@scadasu.com
About Us

SCADASU is a solution platform that digitalizes urban water management from end to end. It reduces water losses, optimizes operations, and prepares cities for the future with smart technologies, SCADA automation, and SUİS water operating system.